PL-2/CPL-2
Standards and Specifications Table
Format | CPL-2 |
---|
Moisture evaporation volume | 0.6 kg/h *1 |
---|
Ethanol evaporation volume | 1.5 kg/h *2 |
*1 Guaranteed capacity is 0.2 kg/h when inlet temperature is 200ºC and outlet temperature is 75ºC.
*2 Guaranteed capacity is 0.3 kg/h when inlet temperature is 140ºC and outlet temperature is 70ºC.
List of Functions
Features |
1. The entire line, from the drying chamber to product recovery, is made of stainless steel.
2. Uses a touch panel. Allows confirmation of device operating status at a glance, and for the collection of operational data.
3. Capable of open operation with only the drying unit when nitrogen circulation is not required.
A nitrogen circulation system can also be added by adding a cooling unit to the back.
4. Can be equipped with an optional CPL-2-specific enclosure unit (dry chamber type).
Enables safer powder production without hampering workability.
[CPL-2 Enclosure]
Exposure: 1 μg/m3 or less
Exhaust method: All exhaust indoor exhaust type (outdoor exhaust is also available)
|
Applications |
Food/Ceramics/Chemical products/Pharmaceuticals/Organic solvents/Other |
Industries |
Electronics industry/Feed industry/Food industry/Chemical industry/Pharmaceutical industry/Vehicle industry/Ceramics industry and fine ceramics/Petroleum resins/Luxury goods |
Specifications |
Heat source (electric heater) Atomizing method (nozzle) Product recovery method (cyclone single-point collection)
|
Remarks |
|